|
|
Sales and Technical Service Support for IDC XplorerTM DR
Xray systems in W.A.
Hightech Labs (Medical)
are Sales and Technical Support Agents for IDC Xplorer equipment in W.A. We look forward to providing you with prompt and
efficient service together with competitive proposals for the outstanding
Xplorer DR Xray systems.
IDC DR vs Analogue
Key Benefits
Higher Patient Throughput
45 seconds vs 8 minutes, No plate processing, Operator
friendly, Instant feedback
Reduced Dose
Variable resolution
More information
More embedded data, 16k grays vs 100+ in analogue, Better
diagnosis
Reduced Cost
No Film and chemicals, No Plate processing, No Replacement
plates, Less Equipment maintenance
Long Technology Life Cycle
Similar to that of Hubble – 50 years
IDC CCD DR vs Flat Plate
DR
Key Benefits
Image Quality
Highest resolution
Highly reliable
Minimal maintenance/replacement, Operator friendly
Long Technology Life Cycle
Reduced Cost
Lower purchase costs, Lower maintenance costs, Modular – easy
upgrade
IDC Xplorer CCD based DR
Overall Advantages
#1 in CCD DR
Global installed base well over 1,000 sites
Excellent reputation
2 sites in Australia to date
Highly reliable
Coupled Charge Device (CCD)
Lower service charges
Excellent Image Resolution
4,600 lp/mm Spatial resolution
Minimised noise
150 um
Low cost high value
Modular low cost manufacture
Very competitive pricing
Ugradeable components
So why use IDC Xplorer™
DR technology?
IDC DR unsurpassed image quality
Optimised noise, resolution, contrast, selectable resolution
Very high reliability
Increased uptime, Reduced service costs, 3 year warranty on
detector
Passive trigger technology
Easy install/retrofit, Economical – only operates when
required
Fast image preview
under 6 seconds
Wide field of view
43cm x 43cm (17”x17”) , Off centre imaging, Easy access to
edge of imaging field.
IDC Passive Trigger Technology
No generator interface required
Easier to install, Easier to retrofit with existing x-ray
generating equipment
Automated capture
Image capture begins automatically when scintillator glows.
Automated display
Image processing and display cycle begins when scintillator
goes dark.
Off centre imaging - Improves access and IQ
Magellan II Workstation
High resolution image capture
Image preview in under 6 seconds
Generator Integration
Control from user interface, Use same viewstation
Post processing tools
Tissue equalization, Sharpening, Auto-crop and auto-shutter
DICOM 3.0 compliant
DICOM Print, Storage SCU, Optional DICOM Modality Worklist ,
SCU and SCP, with MPPS
Please do not hesitate to contact us, if you require further
information, a quotation or a demonstration.
|